| STISP-300 Insulin Pimp Technical Specification | |
| Item | Parameter |
| Range of application | The product is suitable for patients with diabetes who need insulin infusion therapy |
| Size | 78mm×52mm×20mm |
| Weight | 55g(Not included battery) |
| CPU | Double CPU |
| minimum dose | 0.05U |
| Water Resistant | IPX8 |
| Battery | 1 AAA alkaline battery |
| Manu | Open type, some functions can be turned on or off freely |
| Infusion method | Basal infusion, clinical-based infusion, high-dose infusion, square wave infusion |
| Charging method | The screw is automatically reset, and the loaded amount of medicine is automatically calculated. |
| Base rate segment | 24/48 basal rates |
| Base rate setting step amount | 0.1U/0.05U |
| Quick setting of base rate | 24-segment and 6-segment dual database |
| Base rate settings | 0-5U(Or more) |
| Base rate plan | 3 sets can be stored in advance |
| Base rate calibration function | Yes |
| Provisional base rate | Within 24hours, between 0-200%,10% increment or decrement |
| High-dose setting mode | Regular mode and three-meal mode |
| High-dose preset function | Yes |
| High Dose Wizard Calculator | Yes |
| Bolus infusion rate | Adjustable, 4 pulse periods:5s,10s,15s,20s |
| Large dose setting increments | 0.1U |
| High dose limit | 20u (default),Setting 0-85U |
| Daily total limit | 60u (default),Setting 0-200U |
| Daily total review record, Basal rate review record, High dose review record, Exhaust review record, alarm Review record | 50 |
| Warning item | Obstruction, Low dose, drug out, low battery, Meal, Blood sugar measurement, Alarm |
| Meal Tips | Can be opened, meal reminder 10min/20min/30min after high-dose infusion |
| Blood sugar test tips | It can be turned on, and the blood sugar measurement prompt is 1h/2h/3h after high-dose infusion |
| Alarm function | Yes |
| Keyboard lock function | Yes |
| Energy saving | Screen sleep mode |
| Maximum charge | 305U |
| Reservoir volume | 3.0mL |
| Infusion line interface form | Luer interface |
| Warning item parameters: | |
| Low voltage | Low voltage prompt when the voltage is lower than 1.2V |
| Low dose | When the liquid medicine is lower than 20U, the low liquid medicine prompt will be displayed. |
| Drug out | When there is no infusion of liquid medicine, it will alarm when the medicine is finished |
| Block | Blockage alarm before infusion line blockage reaches 6U |
![]()
![]()